Toote toon ja tegelik värvus võivad erineda pildil kujutatust, kuna pildid on illustratiivse iseloomuga. Samuti on toote kirjeldus üldine ega pruugi sisaldada kõiki toote omadusi.
Inverter MUST PV19-4024 EXP, 4kW, single-phase, 24V, 100A MPPT, 500V
529.00 €
Kuumakse alates 14,52 €
3197168 PV19-4024EXP
9990000822409
Tarneaeg 4-7 t.p.
Kauba vastu huvi?
Kõik toote kohta
Solar inverter MUST PV19-4024 EXP, 4kW, single-phase, for 24V battery, PV max. 100A/ 500V/ 5kWFeatures:
Combines the functions of an inverter, MPPT 100A solar charger and battery charger to provide uninterrupted power support while remaining portable.
This inverter does not require a battery to operate.
Operating parameters and priorities can be set on the LCD screen as needed.
Nominal power 4kW. The power of solar panels is up to 5kW.
The maximum PV open circuit voltage reaches 500V DC, MPPT voltage 150~450V DC, which allows full use of solar energy.
Parallel connection is not supported.
Integrated MPPT PV charge controller.
Combines solar, AC or battery power to ensure continuous power.
Allows flexible planning of inverter charging and discharging time.
With USB and RS485 communication interfaces.
Protection against overload, short circuit and deep discharge.
Technical data:
Battery voltage: 24V DC.
Nominal power: 4000W.
Fuse tripping: at 8000VA.
Waveform: True sinusoid.
Battery type: lithium.
Switching time: 10ms/20ms.
Frequency: 50/60Hz.
PV open circuit voltage max.: 500V DC.
MPPT voltage range: 150~450V DC.
Max. solar charge current: 100A.
Power of solar panels: 5000W.
Screen: LCD.
Operating temperature: 0°C ~ +55°C.
Dimensions: 322x486x134 mm.
Weight: 11 kg.
Certificates: CE-EMC+LVD (EN6100-6-3:2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011); EN IEC62368-1:2020+A11:2020; CE-LVD (IEC62109-1:2010, EN IEC62109-2:2011); EN IEC62368-1:2018, EN IEC62109-1:2010, EN IEC62109-2:2011.
Warranty: The warranty of the voltage converter (inverter) is valid from the day when we (the seller) are provided with the serial number of the inverter, the purchase invoice, a certificate from a certified electrician or ESO at the time of delivery of the solar power plant about the installed:
1) Lightning arrester and overvoltage limiter (on the input side)
2) Lightning protection (between solar panels and inverter)
3) DC voltage disconnector between panels and inverter
4) Separate grounding of solar panels, from common house grounding
The 2-year (24-month) manufacturer's warranty is valid from the date of purchase of the inverter upon submission of the above documents.
Note: Lightning strike is an insurable event, not a warranty event.
Specifications
| Nominal battery system voltage | 24V DC |
| Inverter output | |
| Rated power | 4000VA / 4000W |
| Surge power | 8000 VA |
| Waveform | pure sine wave |
| AC voltage regulation (Battery mode) | 230V AC +/- 5% @ 50/60Hz |
| Transfer time | 10ms (UPS/VDE4105) / 20ms (APL) |
| Inverter efficiency (peak) | 92% |
| AC input | |
| Voltage | 230V AC |
| Selectable voltage range | 170~280V AC (UPS) / 90~280V AC (APL) / 184~253VAC (VED4105) |
| Frequency range | 50Hz / 60Hz (Auto sensing) |
| Battery | |
| Normal voltage | 24V DC |
| Floating charge voltage | 27.4V DC |
| Overcharge protection | 30V DC |
| Solar charger AC charger | |
| Maximum PV array open circuit voltage | 500V DC |
| MPPT range @ operating voltage | 150~450V DC |
| Maximum solar charge current | 100A |
| Maximum PV array power | 5000W |
| Maximum AC charge current | 80A |
| Maximum charge current | 100A |
| General specifications | |
| Dimensions(W*H*D) | 322*486*134 mm | Even weight | 11.5 kg |
| Altitude | < 2000 |
| Operating temperature | 0°C to 55°C |
| Humidity range (non-condensing) | 5% - 95% |
| Storage temperature | -15°C to 60°C |