Loading...
Сумма лизинга: 2329.01 €
Frog Cut & Pay | |
Esto lease | |
LHV | |
| | |
Inbank | |
Montonio |




Prekės atspalvis ir tikroji spalva gali skirtis nuo to, kas parodyta nuotraukoje, nes nuotraukos yra iliustracinės. Prekės aprašymas yra bendro pobūdžio ir gali nepateikti visų prekės savybių.
2271350 SG33CX
9990000820221
Pristatymas 2-4 d.d.
Availability date:
| Input (DC) | |
| Max. PV input voltage | 1100 V |
| Min. PV input voltage / Start-up input voltage | 200V / 250V |
| Rated input voltage | 585 V |
| MPP voltage range for nominal power | 550 - 850 V |
| MPP voltage range | 200 V – 1000 V |
| No. of independent MPP inputs | 3 |
| Max. number of PV strings per MPPT | 2 |
| Max. input current per channel | 13 A |
| Max. PV input current | 78 A (3x26A) |
| Max. DC short-circuit current | 120 A (3x40A) |
| Max. current for DC connector | 30 A |
| Output (AC) | |
| Rated AC output power | 33000 W |
| Max. AC output power | 36300 VA |
| Max. AC output apparent power | 36300 VA |
| Max. AC output current | 55.2 A |
| Rated AC voltage | 3 / N / PE, 230 / 400 V, 220 / 380 V |
| AC voltage range | 312 V - 528 V |
| Rated grid frequency | 50 Hz / 60 Hz |
| Grid frequency range | 45 – 55 Hz / 55 – 65 Hz |
| Harmonic (THD) | < 3 % (at rated power) |
| DC current injection | < 0.5 % In |
| Power factor at Rated power / Adjustable power factor | > 0.99/0.8 leading – 0.8 lagging |
| Feed-in phases / Connection phases | 3 / 3 |
| Efficiency | |
| Max. efficiency | 98.60% |
| European efficiency | 98.20% |
| Protection & Function | |
| DC reverse connection protection | yes |
| AC short-circuit protection | yes |
| Leakage current protection | yes |
| Surge protection | DC Type II / AC Type II |
| Grid monitoring | yes |
| DC switch / AC switch | yes / no |
| PV String current monitoring | yes |
| Q at night | yes |
| PID recovery function | optional |
| General Data | |
| Dimensions(W*H*D) | 702*595*310 m |
| Weight | 50 kg | Topology | Transformerless |
| Degree of protection | IP66 |
| Night power consumption | < 2 W |
| Operating ambient temperature range | -30 °C to 60 °C (>45°C derating) |
| Allowable relative humidity range (non-condensing) | 0% – 100% |
| Cooling method | Smart forced air cooling |
| Max. operating altitude | 4000 m (>3000m derating) |
| Display | LED, Bluetooth+APP |
| Communication | RS485 / 4G Optional / Wi-Fi Optional |
| DC connection type | MC4 |
| AC connection type | OT or DT terminal (Max.70 mm²) |
| Grid Compliance | IEC62109-1, IEC62109-2, IEC61727, IEC62116, NB/T32004-2018 |
| Grid Support | LVRT, HVRT, ZVRT, anti-islanding, active and reactive power regulation, PF control, slow start/shutdown |