Device identification
  • Device Name: Shelly EM Gen3

  • Device model: S3EM-002CXCEU

  • Device SSID: ShellyEMG3-XXXXXXXXXXXX

  • BLE Model ID: 0x1027

Short description

Shelly EM Gen3 (hereinafter - the Device) is a small-form smart energy meter using up to 2 current transformers (contactless metering), which allows you to measure the consumption of electrical appliances and provide reports to a mobile phone, tablet, PC or home automation system. It can work autonomously on a local Wi-Fi network or be controlled via cloud home automation services. The device has an internal data storage that allows you to restore them later. The device has one dry contact switch for controlling external loads.

The Shelly EM Gen3 device can be accessed, controlled and monitored remotely from any location where the user has an internet connection, as long as the device is connected to a Wi-Fi access point and the internet.

Shelly EM Gen3 can be installed in standard electrical wall boxes, near electrical appliances, electrical outlets or other places where installation space is limited.

The Shelly EM Gen3 has an integrated web interface that can be used to monitor, configure and control the device.

Main functions
  • Compact forms

  • Single-phase, two-channel measurement

  • Connecting the current transformer

  • Dry contact relay for contactor control

  • Real time clock

  • The device stores up to 10 days of minute data records

Use cases
  • Power consumption monitoring: Monitor the power consumption of connected devices in real time. This information can be valuable in understanding energy consumption patterns and making informed decisions about reducing consumption.

  • Optimizing energy efficiency: Identify patterns of electricity consumption and optimize electricity usage.

  • Checking the health of devices: Track the electricity usage of individual devices to assess their health and performance over time. Sudden spikes or changes in power consumption may indicate problems with the device.

    .
  • Cost management: By knowing your electricity consumption, you can estimate the operating costs of specific appliances and manage your electricity costs more effectively.

  • Efficient space adaptation: The device can be integrated into standard electrical wall boxes, behind sockets, light switches or other places where space is limited.

  • Remote monitoring: Shelly EM Gen3 supports publishing data to the Shelly cloud or other cloud data collection and storage systems, allowing you to monitor energy consumption even when you are away from home.

  • Local Monitoring: Like other devices in the Shelly Wi-Fi line, the Shelly EM Gen3 allows only local monitoring and automation. Access to saved energy consumption records is available directly from the device's user interface. Automate on-site by applying rules based on instantaneous energy consumption or energy consumption over a period of time.

Basic programs
  • Residential premises

  • MDU (Condominiums - apartments, condominiums, hotels, etc.)…

  • Light commercial activity (small office buildings, small retail/restaurant/gas station buildings, etc.)…

  • Industrial (factories, power plants, water treatment plants, oil refineries, etc.)…

    Industrial (factories, power plants, water treatment plants, oil refineries, etc.)

  • State and/or municipal

  • University/College

  • Farming

Simplified internal scheme

smart-energy-meter-shelly-em

Connectivity
  • Wi-Fi

  • Bluetooth

Protocols
  • MQTT

  • HTTP

  • WebSocket

  • RPC

Security feature
  • Internal temperature sensor and its notification

Supported load types
  • Resistive (light bulbs, heating devices)

  • Capacitor (LED drivers, capacitor banks, electronic equipment, motor starting capacitors)

  • Induction (transformers, fans, refrigerators, air conditioners)

User InterfaceInputs
  • One (control) button

    • Press and hold for 5 seconds to enable the device's hotspot and Bluetooth connection.

    • Press and hold for 10 seconds to factory reset your device.

Outputs
  • LED (monochrome) indication

    • With AP (Access Point) on and Wi-Fi off:
      1 second ON / 1 second OFF

    • Wi-Fi is on but not connected to a Wi-Fi network:
      1 second ON / 3 seconds OFF

    • Connected to a Wi-Fi network:
      Always ON

    • Cloud enabled but not connected:
      1 second ON /5 seconds OFF

    • Connected to Shelly Cloud:
      Always ON

    • OTA (Over the Air Update):
      ½ second ON / ½ second OFF

    • The button is pressed and held for 5 seconds:
      ½ second ON / ½ second OFF

    • Button presses and holding for 10 seconds:
      ¼ second ON / ¼ second OFF

The list provided starts with the initial state of the device and the lowest priority. Each subsequent state cancels the previous one.

Specifications

Quantity

Value

Physical

Size (HxWxD):

37x42x16mm / 1.46x1.65x0.63inch

Weight:

  • EM Gen3 - 23 g / 0.81 oz

  • CT 50A - 50 g / 1.76 oz

Maximum torque for screw terminals:

0.4 Nm / 3.5 lbin

Conductor cross-section:

0.2-2.5 mm² / 24-14 AWG (solid, stranded and sleeve terminals)

Conductor length without strips:

6-7mm / 0.24-0.28in

Installation:

Wall console, electrical cabinet

Body material:

Plastic

Sink color:

  • White

  • Charcoal gray

Connector color:

Black

Environmental

Ambient working temperature:

20°C to 40°C / 5°F to 105°F

Humidity:

30-70% RH

Maximum height:

2000 m / 6562 ft

Electric plant

Power supply:

110-240 V~ 50/60 Hz

Electricity consumption:

< 1.2W

Neutral is not required:

Yes or no

External protection:

2 A, actuation characteristic B or C,
6 kA interrupting power,
Energy limitation class 3

Nominal parameters of output circuits

Maximum switching voltage:

240 V~

Maximum switching current:

2 A/240 V~

Switches, gauges

Voltmeter (AC):

110-240 V~ 50/60 Hz

Voltmeter Accuracy:

±2%

Meter (AC):

0 - 80 A

Accuracy of the meter:

±2% (2 - 50 A), ±2% (1 - 2 A), ±5% (0 - 1 A)

Compatible current transformers:

  • CT 50A (included in the package)

  • CT 80A

Electricity and energy meters:

  • Active and apparent power

  • Active and apparent energy

  • Energy coefficient

  • Basic active and basic reactive energy

Minimum inter-channel calibration load:

500 W

Regardless of the load limit:

30 VA per channel

Storage of measurement data:

At least 10 days 1 min. data resolution

Data export:

  • For CSV saved PQ values

  • JSON format export via RPC

Internal temperature sensor:

Yes

Radio

Wi-Fi

Protocol:

802.11 b/g/n

RF band:

2412 - 2472 MHz

Max. RF power:

< 20 dBm

Rank:

30m / 100ft indoors and 50m / 160ft outdoors
(depends on local conditions)

Bluetooth

Protocol:

4.2

RF band:

2402 - 2480 MHz

Max. RF power:

< 4 dBm

Rank:

Over 10m/33ft indoors and 30m/100ft outdoors
(depends on local conditions)

Microcontroller block

CPU:

ESP-Shelly-C38F

Flash:

8 MB

Firmware options

Schedules:

Yes

Webhooks (URL Actions):

20 with 5 URLs in each hook

Scripting:

Yes

MQTT:

Yes

Encryption:

Yes (transport level)

Authentication:

Yes (application and transport layer)

Basic wiring diagrams

smart-energy-meter-shelly-em



A legend

Terminals

Cables

oh

Load circuit output terminal

L

Cord (110-240V)

I

Load circuit input terminal

N

Neutral wire

IA

Input of the first channel current transformer

Current transformers

IB

Second channel current transformer input

CTA

Current transformer of the first channel

L

Connection (110-240 V) terminal

CTB

Current transformer of the second channel

N

Neutral terminal